Taufiqurrahman, M and Toifur, Moh. and Ishafit, Ishafit and Okimustava, Okimustava and Khusnani, Azmi (2020) EFFECT OF SOLUTION TEMPERATURE ON VOLTAGE RANGE AND SENSITIVITY OF LOWTEMPERATURE SENSOR CU/NI RESULTS FROM ELECTROPLATING ASSISTED BY PARALLEL MAGNETIC FIELDS. [Artikel Dosen]
Text (Naskah Publikasi)
15. 2020,M. Taufiqurrahman, Moh. Toifur, Ishafit, Okimustafa, Azmi Khusnani.pdf - Published Version Download (620kB) |
|
Text (Cek Similarity)
15__2020_M__Taufiqurrahman__Moh__Toifur__Ishafit_.pdf Download (2MB) |
Abstract
This study aims to identify the effect of solution temperature aided by parallel magnetic fields on the sensitivity and voltage range of the Cu/Ni sensor as a lowtemperature sensor. Solution temperature was varied from 30°C-70°C. The results of data analysis showed that the highest sensitivity is a sensor which is deposited at a temperature of 60°C with a sensitivity level (0.118 ± 0.004) mV/°C with R2= 0.98 and sensor which has the lowest sensitivity sensor with the deposition temperature of 30°C is (0.0004 ± 0.007) mV/°C with R2= 0.96. In contrast to the sensitivity, the highest voltage range is 39.67 mV owned by the sensor which is deposited at 30°C and 60°C while the lowest voltage range is 32.04 mV as a result of the deposition temperature of 40°C.
Item Type: | Artikel Dosen |
---|---|
Subjects: | L Education > L Education (General) |
Divisi / Prodi: | Faculty of Teacher Training and Education (Fakultas Keguruan dan Ilmu Pendidikan) > S1-Physics Education (S1-Pendidikan Fisika) |
Depositing User: | Ishafit Ishafit |
Date Deposited: | 14 Sep 2024 01:35 |
Last Modified: | 14 Sep 2024 01:35 |
URI: | http://eprints.uad.ac.id/id/eprint/69975 |