Kendali posisi motor DC sangat diperlukan dalam berbagai sistem dinamik. Karaketristik kekokohan pengendalian menjadi salah satu hal yang harus dipertimbangkan dalam pengendalian posisi motor DC. Makalah ini bertujuan untuk mengusulkan metode pengendalian posisi motor DC menggunakan kendali Interval Type 2 Fuzzy Logic (IT2FL). Berbeda dengan pengendali logika fuzzy tipe 1, pengendali ini memiliki fungsi keanggotaan dengan Footprint of Uncertainty (FoU) di setiap variabel linguistik. Kelebihan inilah yang menyebabkan kendali logika fuzzy tipe 2 memiliki karakteristik kekokohan terhadap ketidakpastian parameter sistem. Penelitian ini menggunakan simulasi Matlab/Simulink untuk menunjukkan respon pengendalian dengan penambahan sinyal derau dan dua skenario FoU. Hasil simulasi menunjukkan bahwa pengendali IT2FL menghasilkan performa lebih baik dibandingkan pengendali logika fuzzy tipe 1 dalam mengatasi derau pengukuran. Pada pengendali IT2FL, FoU 0,2 menghasilkan integral error yang lebih kecil dibandingkan FoU 0,1 dengan selisih terkecil sebesar 0,001. Position control of DC motor is indispensable in various dynamic systems. Control robustness characteristics are one of the things that must be considered in controlling the position of a DC motor. This paper aims to propose a DC motor position control method using an Interval Type 2 Fuzzy Logic (IT2FL) controller. Unlike the type 1 fuzzy logic controller, this controller has a membership function with a Footprint of Uncertainty (FoU) in each linguistic variable. The benefits of it cause the type 2 fuzzy logic control to have robust characteristics against the uncertainty of system parameters. This study uses a Matlab / Simulink simulation to show the control response with the addition of a noise signal and two FoU scenarios. The simulation results show that the IT2FL controller produces better performance than the type 1 fuzzy logic controller in overcoming measurement noise. In the IT2FL controller, FoU 0.2 produces an integral error that is smaller than FoU 0.1 with the smallest difference of 0.001.

Item Type: Artikel Umum
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisi / Prodi: Faculty of Industrial Technology (Fakultas Teknologi Industri) > S1-Electrical Engineering (S1-Teknik Elektro)
Depositing User: M.Eng. Alfian Ma'arif
Date Deposited: 26 Jul 2021 02:07
Last Modified: 26 Jul 2021 02:07
URI: http://eprints.uad.ac.id/id/eprint/26991

Actions (login required)

View Item View Item